Applications.
Every job asks something different of the measurement. Per application: what is going on, and where to put the measuring point.
Everyday work, better recorded.
How long the layer stays in the window depends on the layer thickness, the starting temperature, the base, the air and above all the wind. A 2.5 cm surface course on a cool day is below 80 °C within ten minutes; a 10 cm layer takes almost an hour.10
How to measure it One BM-412 per section: a measuring point in the middle of the lane and one near the edge.
No sun, cold air, a free edge.
At night there is no sun and the layer radiates its heat to a clear sky. The free edge cools fastest. The asphalt weather also calculates the night hours, with the spread across the weather scenarios.
How to measure it A measuring point at the free edge next to the middle of the lane; the platform suggests this by itself for night work.
A smaller window, so better to know where you stand.
In the Netherlands producers have not made road asphalt above 140 °C since 2025.5 Starting lower means less room to the bottom of the window. The CROW guideline asks for the temperature to be checked behind the screed and after rolling.6
How to measure it The window of your own mix, from the mix sheet you read in; a measuring point behind the screed in the layer.
Where two lanes meet.
At the longitudinal joint hot mix meets a lane that has already cooled. So the joint cools differently from the middle of the lane. The job screen puts the joint next to the middle: the difference at the first roller pass and the cooling rate, from measured points only.
How to measure it One measuring point on the joint and one in the middle of the lane, in the same box (BM-412).
A deck is not a road base.
A steel or concrete deck draws or holds heat differently from a road base. That is why you measure the bottom of the layer instead of the layer below, and put an extra box at the transition to the approach: the base changes there.
How to measure it Place sensors without damaging the waterproofing; the platform suggests the positions when you choose "bridge deck" for the job.
Voids cool faster.
An open mix cools faster through the voids. The RAW weather check is stricter for porous asphalt and thin surface courses: air at least wind plus five, and for two-layer porous asphalt the season and limits for wind and temperature.12
How to measure it Place the sensors on the underlying layer beforehand: a sensor behind the screed sits loose in the open structure and measures air too.
Does the heat go deep enough?
In in-place recycling, infrared preheaters heat the old surface course and the remixer loosens it, up to six centimetres deep. With infrared heating the difference between top and bottom in a four-centimetre layer can reach 50 °C or more.2 Too cold at the bottom and the layer does not bond; too hot on top and the bitumen ages, quickly above 135 °C.2 Since 2024 we have been measuring on trial sections of a recycling train.
How to measure it Built in beforehand: the measuring point in a saw cut in the old surface course, at the depth you want to follow.
Where the work is interrupted.
At a junction you connect to asphalt laid earlier, and in phased work the work is interrupted: a transverse joint, a next phase. Those are exactly the places the cross-section of a normal section does not show.
How to measure it An extra box at the connection and at every interruption; the platform suggests it when you choose "junction" for the job.
Plan a job with us.
A new surface course, a trial section with the recycling train, a night with low-temperature asphalt? Tell us which job, which layer and which mix. We set up the job in the platform, make the measurement plan and put the box out.
Sources
- Van de Pol, Heating of porous asphalt for in-situ recycling, University of Twente / ASPARi, 2019: thermocouples at 2.0, 3.5 and 4.5 cm; top/bottom difference up to 50 °C at 100 °C surface (Huang et al.); bitumen ageing increases sharply above 135 °C (Yener and Hinislioglu).
- Omgevingsdienst NL, Adviesdocument VTH-aanpak asfaltcentrales, 2024: since 1-1-2025, VBW producers do not make road asphalt above 140 °C (industry agreement, not law).
- Rijkswaterstaat, Asfalteren bij lage temperaturen, ZOAB+ proefvakken A58, 2012: temperature measurements of the underlying layer, also after preheating, with thermocouples in the layer; CROW, Richtlijn Warm Mix Asfalt v1.01, 2024: check the temperature behind the screed and after rolling, dry bonding surface.
- Pavement Interactive, Factors Affecting Compaction (MultiCool): 25 mm at 149 °C, 16 °C air and 16 km/h wind below 79 °C in 9 minutes; 105 mm in 54 minutes.
- CROW, Standaard RAW Bepalingen (the Netherlands), 81.22.03: measure the temperature and wind speed on site, at 1 m above ground; no paving below 5 °C; for porous asphalt and thin surface courses air at least wind + 5; for two-layer porous asphalt 1 April to 1 November and limits for wind and temperature.