What to expect.
From the weather, the layer and the measurement: when the layer is in the rolling window, when it leaves it, and when it is cool enough to open.
Rolling happens within a temperature window. We show when the layer is in it.
Compaction only works while the asphalt is warm enough. For hot mix that window runs roughly from 150 °C behind the screed down to 70 to 80 °C: below that the bitumen stiffens and a roller pass adds no more density.89 Rolling too hot causes shoving and cracking. The limits for your mix are in its laying instructions.
How long the layer stays in that window depends on layer thickness, starting temperature, the base, the air temperature and above all the wind. A 2.5 cm surface course drops below 80 °C within ten minutes on a cool day; a 10 cm layer takes almost an hour.10 With wind above 5 m/s, 40 to 50 percent less rolling time is available.8
The roller operator only sees the surface, and it cools faster than the core. In wind or cold the surface is already too cold while the layer inside is still warm enough, or the other way round.911 The Sensorbox measures the temperature inside the fresh layer, at a fixed spot. The Verboom Platform also knows the air temperature and the wind at the site. From the measured cooling and the weather follows the expected moment the layer enters the window and the moment it drops out. And afterwards it is in the record: how warm the layer was at the first roller pass, and when it fell below the limit.
The expected cooling adjusts to the measurement.
A model that only calculates beforehand does not know what the layer actually does. Our model starts at laying with what it knows, and adjusts every minute to the measurement in the layer.
Physics, not a rule of thumb
Heat through the layer and the base, with wind, sun, radiation and the air temperature at the location of the job.
With the spread included
The model calculates 48 variants of the layer at once and keeps the variants that follow the measurement. So you see not only when the layer leaves the window, but also the earliest and the latest moment.
Fallback when needed
If the calculation service is briefly unavailable, the platform carries on with the simple model. The job screen keeps working.
Checked afterwards
Per job you see how good the expected cooling was: 5, 10, 15 and 20 minutes before the layer left the window, next to the simple model and a straight line. As the expected cooling was at the time, not fitted afterwards.
Cool enough to open.
When the road opens is decided by the site manager or the client. The platform shows when the layer reaches the limit you set, and reports it by app, text, email or on the led tower.
What if the next section starts later?
For the next section
Now, in a quarter of an hour or in half an hour; ten degrees colder; more wind; a thinner or thicker layer. Per scenario the rolling time and when the layer is cool enough.
Learning per mix
Every measured layer adjusts the model for that mix and that base. The next job starts from there instead of from the default.
Your data stays yours
What you measure and what the model learns from your jobs stays within your company. Sharing with other companies, the benchmark and the shared model for standard mixes, happens only if you switch it on yourself. Then only in summary: never who, where or when.
State of the art, and built in-house.
We have been calculating with temperature for almost forty years: that is how long the Netherlands has determined the maturity of concrete with our measuring systems. For asphalt we built our own calculation model on that. It combines what the layer does, what the weather will do and what the weather actually did.
Not a weather report with a rule of thumb, but physics, 91 scenarios and a measurement. And every layer you measure makes the expected values for that mix sharper.
- Coolingheat through layer and base, with wind, sun and radiation; calibrated on the published cooling tables10
- Weather91 scenarios from the European weather centre and the German weather service13
- Measurementthe hourly weather of the KNMI, with the wind at 1 m as the RAW measures it14
- Learningevery measured layer adjusts the model, per mix
Plan a job with us.
A new surface course, a trial section with the recycling train, a night with low-temperature asphalt? Tell us which job, which layer and which mix. We set up the job in the platform, make the measurement plan and put the box out.
Sources
- CROW, Richtlijn Warm Mix Asfalt (Warm Mix Asphalt guideline) v1.01, 2024, table 2: indicative working window for conventional hot mix 150 → 70 °C, set per mix in the laying instructions; CROW Kennisbank, Verdichtingsresultaat (compaction result): above 5 m/s the layer cools significantly faster, "roughly 40 to 50% less rolling time".
- Harman and West, Recommended Asphalt Mixture Temperature Specifications for Paving Projects, NCAT Report 26-03, 2026: lower limit about 80–85 °C for dense-graded mixes; infrared measures the surface and underestimates the core temperature in wind or cold.
- Pavement Interactive, Factors Affecting Compaction (MultiCool): 25 mm at 149 °C, 16 °C air and 16 km/h wind below 79 °C in 9 minutes; 105 mm in 54 minutes.
- Bijleveld, Miller, De Bondt and Dorée, Too hot to handle, too cold to control, Eurasphalt & Eurobitume 2012: the surface cools faster than the middle of the layer; the middle can still be too hot while the surface is already too cold.
- ECMWF, ENS ensemble (51 scenarios), and Deutscher Wetterdienst, ICON-EPS (40 scenarios); fetched hourly via Open-Meteo.
- KNMI, Hourly weather data of the Netherlands (daggegevens.knmi.nl): temperature, hourly mean wind at 10 m and precipitation per station. The wind at 1 m follows from the logarithmic wind profile for open terrain.